Welcome to our comprehensive collection of Multiple Choice Questions (MCQs) on Mass Spectrometer, a fundamental topic in the field of Analytical Instrumentation. Whether you're preparing for competitive exams, honing your problem-solving skills, or simply looking to enhance your abilities in this field, our Mass Spectrometer MCQs are designed to help you grasp the core concepts and excel in solving problems.

In this section, you'll find a wide range of Mass Spectrometer mcq questions that explore various aspects of Mass Spectrometer problems. Each MCQ is crafted to challenge your understanding of Mass Spectrometer principles, enabling you to refine your problem-solving techniques. Whether you're a student aiming to ace Analytical Instrumentation tests, a job seeker preparing for interviews, or someone simply interested in sharpening their skills, our Mass Spectrometer MCQs are your pathway to success in mastering this essential Analytical Instrumentation topic.

Note: Each of the following question comes with multiple answer choices. Select the most appropriate option and test your understanding of Mass Spectrometer. You can click on an option to test your knowledge before viewing the solution for a MCQ. Happy learning!

So, are you ready to put your Mass Spectrometer knowledge to the test? Let's get started with our carefully curated MCQs!

Mass Spectrometer MCQs | Page 10 of 14

Q91.
Which of the following is not the characteristic of ICP spectrometer?
Discuss
Answer: (c).High detection limits
Q92.
ICP spectrometer is a sequential multi-element analyser that has scan times less than ____ for one sweep.
Discuss
Answer: (b).20ms
Q93.
Double focussing section analysers offer better resolution than ICP spectrometry system.
Discuss
Answer: (a).True
Q94.
The most common type of ion detector found in ICP system is which of the following?
Discuss
Answer: (b).Channeltron
Q95.
Which of the following is the most accurate method of determination of elemental composition?
Discuss
Answer: (b).Isotope dilution
Discuss
Answer: (d).Not useful for detection of non-metals
Q97.
The isobaric interference is not caused in which of the following elements?
Discuss
Answer: (c).Helium
Q98.
Which of the following is the most sensitive of the spectral methods?
Discuss
Answer: (b).Mass spectroscopy
Discuss
Answer: (d).It does not provide direct identification
Q100.
Cold tray is provided for liquid N₂ or CO₂ but is used only for extremely small samples.
Discuss
Answer: (a).True