Welcome to our comprehensive collection of Multiple Choice Questions (MCQs) on Measurements and Instrumentation, a fundamental topic in the field of Electronics and Communication Engineering. Whether you're preparing for competitive exams, honing your problem-solving skills, or simply looking to enhance your abilities in this field, our Measurements and Instrumentation MCQs are designed to help you grasp the core concepts and excel in solving problems.

In this section, you'll find a wide range of Measurements and Instrumentation mcq questions that explore various aspects of Measurements and Instrumentation problems. Each MCQ is crafted to challenge your understanding of Measurements and Instrumentation principles, enabling you to refine your problem-solving techniques. Whether you're a student aiming to ace Electronics and Communication Engineering tests, a job seeker preparing for interviews, or someone simply interested in sharpening their skills, our Measurements and Instrumentation MCQs are your pathway to success in mastering this essential Electronics and Communication Engineering topic.

Note: Each of the following question comes with multiple answer choices. Select the most appropriate option and test your understanding of Measurements and Instrumentation. You can click on an option to test your knowledge before viewing the solution for a MCQ. Happy learning!

So, are you ready to put your Measurements and Instrumentation knowledge to the test? Let's get started with our carefully curated MCQs!

Measurements and Instrumentation MCQs | Page 20 of 51

Discover more Topics under Electronics and Communication Engineering

Q191.
Consider the following instruments

1. Tangent galvanometer
2. Rayleigh current balance
3. Household energy meter
4. Hot wire ammeter

Out of above absolute instruments are
Discuss
Answer: (c).1 and 2
Q192.
A 0-150 voltmeter has a guaranteed accuracy of 1% of full scale reading. If actual reading is 83 V, the percentage error is
Discuss
Answer: (c).1.81%
Q193.
In a CRO, the frequency of output of time base generator
Discuss
Answer: (b).is adjustable
Q194.
If A = 131 ± 4 and B = 106 ± 4, the percentage range of doubt in A - B is
Discuss
Answer: (d).32%
Q195.
Two resistance R1 and R2 are connected in series R1 = 528 ± 5 ฮฉ and R2 = 325 ± 3ฮฉ. The total resistance will be
Discuss
Answer: (d).853 ± 8 ฮฉ
Discuss
Answer: (a).by pass the current
Q197.
Which of the following does not use the principle of change in inductance?
Discuss
Answer: (c).Strain gauge
Q198.
It is necessary to measure the amplitudes of two signals and also the phase difference between them. This can be done by using a
Discuss
Answer: (b).waveform meter
Q199.
An amplifier has to amplify pulses of 1 H-s duration. The minimum bandwidth of amplifier must be
Discuss
Answer: (d).1 MHz
Q200.
A moving coil meter has a resistance of 50 ohms and a full scale deflection current of 20 mA. To convert it into a voltmeter of 0-100 V range, the series resistance should be
Discuss
Answer: (c).4950 ฮฉ